• 12V Battery for Medical Infusion Pump
  • 12V Battery for Medical Infusion Pump

12V Battery for Medical Infusion Pump

Type: Ni-MH/Ni-CD Battery Pack
Connection Mode: Series Connection
Rechargeable: Chargeable
Discharge Rate: Low Discharge Rate
Size: Small
Accessories Type: Battery
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Gold Member Since 2018

Suppliers with verified business licenses

Guangdong, China
to see all verified strength labels (25)

Basic Info.

Model NO.
HAA2200-B5*2
Rated Capacity
2200mAh
Standard Voltage
12V
Usage
Remote Control Boat, Remote Control Plane, Remote Control Car, Medical Products
Electrolyte
Alkaline
Shape
Cylindrical Cell
Cell or Battery
Battery Pack
Warranty
1 Year
Flat/Button Top
Flat Top Battery
Fittings
with Connector
Certificates
Conform to UL, CB, Un, etc.
Transport Package
Carton Box
Specification
AA
Trademark
JYH
Origin
Guangdong, China
HS Code
85076000
Production Capacity
500000PCS/Day

Product Description

12V Battery for Medical Infusion Pump

Features
1. Wide range of working temperature
2. Long endurance life
3. Stable discharge platform


Specification of NiMH AA 1.2V 2200mAh Cell
Nominal Voltage 1.2V
Nominal Capacity 2200mAh
Typical Capacity 2270mAh after standard charge and standard discharge
Standard Charge 220mA for 16hrs.
Standard Discharge 440mA to 1.0V.
Fast Discharge 1100mA to 1.0V.
Maximum Continuous Discharge Current 6600mA
Operating Temperature Standard charge 0ºC to 40ºC
Fast charge 10ºC to 35ºC
Trickle charge 0ºC to 40ºC
Discharge -20ºC to 50ºC
Dimensions Diameter 14.5mm
Height 50.0mm
Typical Weight 27.5g

Product Photos
12V Battery for Medical Infusion Pump
Applications
1. Electric products/ solar energy/ storage systems
2. Home applications/ fan
3. Solar light/ flashlight/ digital products/toys
4. Emergency lighting/ emergency light/ emergency luminaries
5. Medical Device
6. Evacuation system
7. Backup power
8. Other


Shipment
By air or ship. It depends on customer requirements and goods quantity.

Certificates
12V Battery for Medical Infusion PumpISO 9001:2015
It is a globally recognized standard for quality management. It helps improve performance, meet customer expectations and demonstrate commitment to quality.
ISO 14001:2015
It is the internationally recognized standard for environmental management systems (EMS). By adhering to this standard, we can ensure taking proactive to minimize environmental footprint, comply with relevant legal requirements, and achieve environmental objectives.
IEC 62133-2:2017
Safety requirements for portable sealed secondary cells, and for batteries - Part 2: Lithium systems
Globally recognized certificate, and this standard specially for European market requirements.
UL 1642
These requirements cover secondary (rechargeable) lithium batteries for use as power sources in products, specially for Li-ion cell in North American market requirements.
UL 2054
These requirements cover secondary (rechargeable) lithium batteries for use as power sources in products, specially for Nickel cell & battery pack and Li-ion battery pack in North American market requirements.
KC
Korea Certification, Korea electronic and electrical supplies safety certification regulation, Korea market requirement.
PSE
The PSE certification is a mandatory safety certification in Japan.
BIS
India market requirement, BIS (The Bureau of India Standards), specigically responsible for product certification.
IEC 62620
Secondary lithium cells and batteries for use in industrial applications.
This is also a requirement of Lithium batteries in emergency lighting (IEC 60598-2-22) standard, ensure the lithium battery meet requirements of discharge/ endurance performance etc.
IEC 61951
Secondary sealed cells and batteries for portable applications.
This is also a requirement of Nickel batteries in emergency lighting (IEC 60598-2-22) standard, ensure the Nickel battery meet requirements of discharge/ endurance performance etc.
Battery Directive
Battery Directive (Directive 2006/66/EC), restricting hazardous substances in batteries. It continues to restrict the use of mercury and cadmium in batteries and introduces a restriction for lead in portable batteries.
ROHS (Components)
Restriction of Hazardous Substances in Electrical and Electronic Equipment (RoHS)
This is EU laws restriction for harmful (hazardous) substances such as lead, mercury and cadmium, which can cause major environmental and health problems.
Battery testing standard is according to 200/66/EC.
UN 38.3
UN Manual of Tests and Criteria Part III Item 38.3, which includes requirements regarding Li-ion batteries.
This is transportation requirement for Li-ion cells and batteries.
Transportation
It devides into air and sea transportation report. For battery transportation, it is required to have this certification.


Company Tour
12V Battery for Medical Infusion Pump12V Battery for Medical Infusion Pump12V Battery for Medical Infusion Pump

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Gold Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Plant Area
15244 square meters
Management System Certification
ISO9001:2015, ISO14001:2015