Customization: | Available |
---|---|
Type: | Li-ion Battery |
Cathode Material: | LFP |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | LFP18500-1000 2S1P |
IEC Designation | 2IFpR19/50 |
Nominal Voltage | 6.4V |
Nominal Capacity | 1000mAh |
Typical Capacity | 1000mAh after standard charge and standard discharge |
Minimum Capacity | 950mAh after standard charge and standard discharge |
Standard Charge | Constant current at 200mA charge to 7.3V, then constant voltage at 7.3V charge till current decline to ≤20mA |
Fast Charge | Constant current at 1000mA charge to 7.3V, then constant voltage at 7.3V charge till current decline to ≤20mA |
Standard Discharge | 200mA to 5V |
Fast Discharge | 500mA to 5V |
Maximum Continuous Charge Current | 0~10ºC 200mA 10~20ºC 500 mA 20~60ºC 1000 mA |
Maximum Continuous Discharge Current | 1000mA |
Operating Temperature | Charge 0ºC to 60ºC Discharge -10ºC to 70ºC |
Storage Temperature | <1 year -20ºC to 25ºC <3 months -20ºC to 40ºC <30days -20ºC to 50ºC |
Typical Weight | 63g |
PCM Electrical Characteristics | PCM Parameters are adjustable depends on different solutions |
Overcharge detection voltage | 3.90±0.025V |
Over-discharge detection voltage | 2.00±0.050V |
Overcurrent detection current | 3-6A Cut load, recover after charging |
Short detection condition | Exterior short circuit Cut load, recover after charging |
PTC | Available. Mounted on PCM/BMS, or external solution. |
NTC | Available. Mounted on PCM/BMS, or external solution. eg. 10kΩ, B=3435. |